whatsapp
Brand EATON UPS System On Line UPS Eaton Make 20 KVA 3/1:3/1 Phase Rack Mountable On-Line UPS

Eaton Make 20 KVA 3/1:3/1 Phase Rack Mountable On-Line UPS

DXRT20KS-IN

UPS System On Line UPS

Price: 206500

MRP 394252.16 You save 187752.16

Eaton DX-RT (6-10 kW)

New Eaton DX-RT is a true online double conversion Rack and Tower Convertible UPS system that affordably provides Robust, Reliable, Compact and Efficient Power Management Solution for Mission Critical Application from downtime, data-loss. Eaton DX-RT delivers more power in a limit space (2U) and saves energy cost due to it’ highly efficiency design and offers efficiency upto 95% in online mode. Eaton DX-RT perfectly fits harsh Indian environmental and power condition and Provide much stronger protection on inrush current and it improves it’s adaptability to grid power condition

Eaton DX-RT - Features

  • IGBT Based Rectifier True Online Double Conversion
  • New Graphical LCD Display.
  • Rack & Tower Convertible, Higher power density (only 2u and <600mm depth for10K)
  • Wide Input Voltage window (110 – 275Vac) for Indian Environmental Condition.
  • Double Conversion Efficiency upto 95%.
  • Active Input Power Factor Correction 0.99.
  • Unity Output Power Factor.
  • Inbuilt OVCD (Over Voltage Cut-off device)
  • Generator Compatible with Wide Input voltage window
  • Frequency Range (40 Hz-70 Hz).
  • Digital Charger Technology provide 0-12 A charging current.
  • Adjustable Battery no’s 16/17/18/19 and 20.
  • 50/60 Hz Automatic Frequency Converter Mode.
  • WINPOWER software support virtualization transfer application Intelligent Monitoring options.
  • Product Performance and its Benefits.

  • High Performance
  • kVA=kW.

    Rack and Tower Convertible

    Form Factor 2U with <600 mm Depth.

    True Input PF 0.99

    True output Unity PF 1.

    Input THDi 3%.

    Output THDv 1%.

    Higher Power Density.

    Higher Efficiency upto 95%.

    Support Critical Virtualization.

  • High Reliability and Adaptability
  • Wide Input Voltage Range

    Inbuilt Hardware Current Limit Technology.

    Upgraded Phase Lock Algorithm

    Inbuilt Over-voltage Cut-off Device

    Inbuilt Over Temperature Protection.

    Upto 50 Degree Celsius operation @50% Load (Specific to XL Model)

    Better Overload Protection upto 105% Constant

  • High Flexibility and Availability
  • Adjustable Battery Voltage 192 Vdc-240 Vdc.

    Adjustable Charging Current 0 A-12 Amps

    Parallel Operation upto 3 UPS’s.

    Better Short Ckt Handling Capacity.

    Auto Fault Recovery.

    Inbuilt Maintenance Bypass Switch.

    Conformal Coated Boards.

    PDU and MBS 2-in-1 kit support easy maintenance.

    More Accessories.

  • Major Application
  • Networking and Server Equipment.

    Small and Micro Data Centre application

    Bio-Metrics/Radiology and Medical Equipment.

    Security and Surveillance System/CCTV and CAMERA.

    Pritner/IT-Load and PC's.


    Reset default

    Specification

    Output Specification
    Output Capacity (KVA )
    20 KVA
    Output Capacity (KW )
    20 KW
    Output Power Factor
    1 Power Factor
    Output Phase
    3 Phase
    Other Output Phase
    1 Or 3 Phase
    Output Voltage
    400 Volt
    Other Output Voltage
    380 Or 415 Volt
    Efficiency at Full Load
    > 94 %
    Output Voltage Distortion
    < 1 %
    Load Crest Factor
    3:1
    Output Voltage THD
    < 3 %
    Output Waveform type
    Sine Wave
    Output Connections
    Hard Wire 3 wire (1PH+N+G), Hard Wire 5-wire (3PH + N + G)
    UPS Parallel Upto
    3 Nos.
    General Specifications
    Flexible Battery Option
    Yes
    Isolation Transformer
    Optional
    Paralleling Options
    Yes
    Rack Mounting Kit
    Optional
    Paralleling Kit for Synchronising
    Optional
    Input Specification
    Input Voltage
    400 Volt
    Other Input Voltage
    380 Or 415 Volt
    Input Phase
    3 Phase
    Other Input Phase
    1 Or 3 Phase
    Input Voltage Range (Output Derated)
    110 - 275 Volt
    Input voltage range for main operations
    160 - 275 Volt
    Input frequency Range
    45 - 55 Hz
    Input Power Factor
    > 0.99
    Input Connections
    Hard Wire 3 wire (1PH+N+G), Hard Wire 5-wire (3PH + N + G)
    Batteries & Runtime
    Battery DC Bus
    384 - 480 VDC
    Maximum Charger Capacity
    12 Amp.
    Battery Position Option
    External
    Battery Type Compatibility
    SMF Battery
    Batteries Recharge Time upto 90%
    < 5 Hrs.
    Approved Battery Capacity (AH)
    17 - 200 Amp.
    Communication & Management
    Control panel
    LCD Display
    SNMP Management
    Optional
    Power Management Software
    In-Built
    Interface Port(s)
    RS-232, USB
    Physical
    Maximum Height
    129 Mm
    Maximum Width
    438 Mm
    Maximum Depth
    589 Mm
    Net Weight
    23.7 Kg
    Rack Height(U)
    3 U
    Environmental
    Operating Temperature
    0 - 40 °C
    Operating Relative Humidity
    0 - 95 % Rh
    Other Specifications
    Technology
    Double Conversion Online

    Documentation

    Item Catalogue
    eaton-dxrt-ups-Catalogue-10 KVA 3 Phase 1 Phase 3:1
    pdf
    Eaton-dxrt-ups-brochure-15-20kva
    pdf

    Options

    Services

    Contact Us