Brand APC UPS Accesories Rack PDU APC Make Vertical Rack PDU 2G, Metered, ZeroU, 11kW, 230V, (36) C13 & (6) C19

APC Make Vertical Rack PDU 2G, Metered, ZeroU, 11kW, 230V, (36) C13 & (6) C19

AP8881

UPS Accesories Rack PDU

Price: 56050

MRP 115876 You save 59826

Rack PDU 2G, Metered, ZeroU, 11kW, 230V, (36) C13 & (6) C19

APC Metered Rack Power Distribution Units (PDUs) AP8881 provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.

Includes: Installation guide, Rack mounting brackets, Safety guide, Serial configuration cable

Key Features

  • Output Connections
  • (6) IEC 60320 C19

    (36) IEC 60320 C13

  • Nominal Output Voltage
  • 230 V

  • Nominal Input Voltage
  • 200V, 208V, 230V

  • Input Connections
  • IEC 60309 16 A 3P + N + PE, IEC 60309 20 A 3P + N + PE

  • Approvals
  • CSA C22.2 No 60950, IEC 60950, UL 60950-1, VDE


    Reset default

    Features

    NetShelter Metered Rack PDUs Features & Benefits
    Agility
    Rack-Mountable
    Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in
    Single input power source
    Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount
    Wide range of input and output connections
    Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V
    Availabilty
    60C Operating Temperature
    All 8000 and 9000 series PDUs now provide the ability to operate in a maximum ambient air temperatur
    Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the
    Load indicator LED
    Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users o
    Local Current Monitoring Display
    The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local di
    Flash Upgradeable
    Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates
    Integrates with StruxureWare Data Center Expert
    An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical al
    Remote Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web, SNMP, a
    Marketing Features
    Local Current Monitoring Display
    The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local di
    Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the

    Specification

    Output Specification
    IEC 60320 C19 Output Sockets
    06 Nos.
    IEC 60320 C13 Output Sockets
    36 Nos.
    Output Capacity (VA )
    11000 VA
    General Specifications
    Standard Warranty
    2 Year(s)
    Capacity
    16 Amp.
    Input Specification
    Input frequency
    50 Or 60 Hz
    Physical
    Maximum Height
    1791 Mm
    Maximum Width
    56 Mm
    Maximum Depth
    44 Mm
    Net Weight
    6.38 Kg
    Colour
    Black
    Environmental
    Operating Temperature
    -5 - 60 °C
    Operating Relative Humidity
    5 - 95 % Rh

    Documentation

    Item Catalogue
    APC_PDU pocket guide FINAL
    pdf