Air Conditioner Precision Air Conditioner
Price:
MRP You save 0
3.5kW split system Indoor unit, Gravity Drain
Rack Mounted cooling solution to meet the specific needs of Micro Data Center and Edge computing solutions
Includes: 120/240 V power supply, Built-in modbus protocol adapter
ACRMD4KI-1 Features
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Removes dirt and other particulates from the intake air for cleaner supply air.
Returns the unit to its last operating status in the event of a power failure.
Measures how much IT load is being cooled by the unit in real time.
Scroll and screw compressors utilize few moving parts for increased reliability and life expectancy
Designed for high-sensible heat ratios, the coil is constructed with copper tubes, raised lance type aluminum fins, and 18 gauge galvanized steel end plates. Coil headers are equipped with anti-drip shields in the event of condensation.
Dehumidification is achieved without any reduction in airflow rate, ensuring continuous and uniform air distribution.
Simplifies future planning by allowing side to side equipment to be placed anywhere in the data center.
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Increases the capacity of the air conditioner by supplying a warmer return air temperature.
Isolates hot exhaust air, ensuring consistent supply air to IT equipment.
Optimize the unit operation at any load or ambient condition, guaranteeing an extremely low power consumption
Higher rate of heat removal allows more equipment to be installed in each rack
Delivers cool, conditioned air directly to the inlet of IT equipment.
Part loading of compressors during start-up ensures low starting torque on the mechanical system with lower inrush current on the electrical system. (only for IS** and BC** models)
Refrigerant cooling system will operate from 0 - 100% of the design capacity
Containment of both front and rear provides reduction of noise caused by installed equipment.
Helps to maintain proper rack temperatures within the enclosure by promoting top to bottom airflow movement.
Full load operation in less than 3 minutes with specific arrangements permits undersizing of the storage tanks
Modular design provides scalable solutions to add cooling as demand increases.
The unit includes both top and bottom piping connections.
Enables the fans to be soft started, saving energy during power up. Controlling the motor speed simplifies the adjustment for static pressure and gives the option of back-draft prevention.
Controls fan speed based on temperature with selectable set points.
Variable speed fans reduce energy consumption during off-peak cooling periods.
Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.