The Amplon RT Series 5-20kVA is an online double-conversion UPS that provides best-in-class designs in compact 2U size, high power density, system efficiency, and versatile configurations to fulfill customers' requirements. Unity output power factor maximizes capacity for more critical loads, while outstanding energy savings can be achieved based on the AC-AC efficiency of up to 96.5% and 99% in ECO mode. In addition, RT Series 5-20kVA UPS is the first in the market that offers standard Li-ion external battery cabinets, which deliver better power density and sustainability. Along with the parallel capacity of up to four units, the new series is the ideal small power UPS for mission-critical applications, such as servers, data centers, telecommunications, and manufacturing


Reset default

Features

Amplon RT Series Features
Availability & Flexibility
True online double-conversion topology and zero transfer time to battery provides 24/7 full-time protection
Wide input voltage range allows the UPS to operate in harsh electrical environments and extends battery life
AC-start function allows the UPS to be switched on without connecting to a battery
Programmable load bank disconnects non-critical loads when a blackout occurs and reserves more battery power for critical loads
Up to four units parallel capacity allows redundancy and load expansion
Hot swappable batteries ensure continuous operation even when batteries are being replaced
VRLA and Li-ion External Battery Cabinet (EBC) are available for scalable runtime
Extended Runtime models support flexible battery quantity for battery investment optimization. And when one battery fails, it could be removed without replacing the entire battery string, reducing maintenance cost and efforts
The Power Distribution Box (PDB) and Maintenance Bypass Breaker (MBB), which are default to RT 5-10kVA Standard Runtime models, enable simple configuration
The Maintenance Bypass Breaker (MBB) is optional for easy UPS replacement without powering down critical systems
The rRPP (Rack Remote Power Panel), which can be integrated with standard server racks, simplifies power output distribution and power monitoring
Common battery configuration is supported in RT 15/20kVA parallel mode to save installation space and additional battery costs
Efficiency & Reliability
Unity output power factor guarantees no de-rating with loads and provides permanent 100% kW
Best-in-class AC-AC efficiency of up to 96.5% and 99% in ECO mode lowers energy costs
Automatic fan speed control maximizes system efficiency and significantly reduces audible noise and prolongs battery life
Fan failure detection sends early warnings to facilitate predictive maintenance of UPS
Manageability
Intelligent battery management to extend battery life and maximize battery performance. The battery aging detection monitors battery status for predictive maintenance, and the 3-stage charging mechanism keeps the battery from continuous float charging during the intermission stage to prolong battery life
Excellent local management through a user-friendly graphical and multi-lingual LCD display
Various types of communication interfaces, including USB, RS-232, and RS-485 ports, mini slot, REPO/ROO for remote management, and in-built dry contacts for monitoring and notification of system operation conditions
UPS management software such as ShutdownAgent and InfraSuite Device Manager allow users to monitor UPS status and protect critical devices

Specification

Output Specification
Output Capacity (KVA )
5 KVA
Output Capacity (KW )
5 KW
Output Power Factor
1 Power Factor
Output Phase
1 Phase
Output Voltage
230 Volt
Other Output Voltage
200 Or 240 Volt
Efficiency at Full Load
> 95.5 %
Output Voltage Distortion
<3 %
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Output Frequency (not synced)
60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
Load Crest Factor
3:1
Output Voltage THD
<3 %
Output Waveform type
Sine Wave
UPS Parallel Upto
4 Nos.
General Specifications
Flexible Battery Option
Yes
Isolation Transformer
Optional
Paralleling Options
Yes
Rack Mounting Kit
Optional
Paralleling Kit for Synchronising
Inclusive
Input Specification
Input Voltage
230 Volt
Other Input Voltage
200 Or 240 Volt
Input Phase
1 Phase
Input frequency
50/60Hz +/- 3 Hz
Input Voltage Range (Output Derated)
110 - 280 Volt
Input voltage range for main operations
140 - 280 Volt
Input frequency Range
40 - 70 Hz
Batteries & Runtime
Approved Battery Capacity (AH)
17 - 100 Amp.
Battery DC Bus
192 - 264 VDC
Maximum Charger Capacity
8 Amp.
Battery Position Option
External
Battery Type Compatibility
SMF Battery
Communication & Management
Control panel
Multi-Language LCD + Status LED
SNMP Management
Optional
Power Management Software
In-Built
Interface Port(s)
RS-232, USB
Audible Alarm
Audible and visible alarms prioritized by severity
Physical
Maximum Height
89 Mm
Maximum Width
440 Mm
Maximum Depth
430 Mm
Net Weight
10.9 Kg
Rack Height(U)
2 U
Environmental
Operating Temperature
0 - 55 °C
Operating Relative Humidity
5 - 95 % Rh
Other Specifications
Technology
Double Conversion Online

Documentation

Item Catalogue
RT Series 5-20 kVA UPS Catalogue
pdf
Item Manuals and Warranties
RT Series 5-10 kVA UPS External Battery Pack User Manual
pdf
RT Series 5-10 kVA User Manual
pdf
RT Series 5-10 kVA UPS Extended Runtime Model User Manual
pdf

Options

Contact Us