Brand DELTA UPS System On Line UPS Delta Make 3 KVA 1:1 Phase On-Line UPS with In-Built Battery (INX Series)

Delta Make 3 KVA 1:1 Phase On-Line UPS with In-Built Battery (INX Series)

Amplon INX 3kVA(SB)

UPS System On Line UPS

Price: 40710

MRP 102542 You save 61832

Reliability for the most critical moments The INX series is an online double-conversion UPS providing consistent sine-wave power to your critical equipment. The INX series features an input power factor corrector and best-in-class AC-AC efficiency of up to 90% resulting in greater energy savings. The INX series leads the industry in combining compact size, availability, flexibility and best total cost of ownership.


Reset default

Features

Amplon INX Series Features
Availabilty
True online double-conversion topology and zero transfer time to battery ensure high reliability
High input power factor corrector (> 0.99) for controlled sine wave AC output
Cold-start capability with temporary battery power when the utility power is out
Automatic bypass to transfer the load on mains in case of overload & internal fault
Battery deep discharge protection
Flexibility
Excellent local communications through user friendly LCD display
Intelligent management software connectivity via RS232, mini slot or USB port
Three multi-functional buttons for the operation and selection of parameters
Cost of Ownership
Protection against over voltage; charger working even when the input switch is in off position
ECO mode to provide energy cost savings
Wide input voltage range to reduce the chance of using the battery and to extend battery life
Intelligent battery management sustaining battery life and performance
Fan speed control by load level and room temperature to optimize performance

Specification

Output Specification
Output Capacity (KVA )
3 Kva
Output Capacity (KW )
2.7 Kw
Output Power Factor
0.99 Power Factor
Output Phase
1 Phase
Output Voltage
220 Volt
Other Output Voltage
230 Or 240 Volt
Efficiency at Full Load
>90 %
Output Voltage Distortion
<2 %
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Load Crest Factor
3:1
Output Voltage THD
<3 %
Transfer Time
<0 Ms
Output Waveform type
Sine Wave
Output Connections
3 Pin Indian Socket (04 Nos.)
General Specifications
Isolation Transformer
Rack Mounting Kit
Input Specification
Input Voltage
220 Volt
Other Input Voltage
230 Or 240 Volt
Input Phase
1 Phase
Input frequency
50/60Hz +/- 3 Hz
Input Voltage Range (Output Derated)
110 - 280 Volt
Input voltage range for main operations
160 - 280 Volt
Input frequency Range
40 - 70 Hz
Input Power Factor
>0.99 None
Input Connections
3-Pin 6A Indian Socket
Batteries & Runtime
Internal Battery Capacity (VAH)
648 - VAH
Approved Battery Capacity (AH)
9 - Amp.
Battery DC Bus
72 - VDC
Maximum Charger Capacity
1 Amp.
Battery Position Option
Internal
Communication & Management
Control panel
Multi-function LCD status and control console
Audible noise at 1 meter from surface of unit
<50 Decibal
Physical
Maximum Height
325 Mm
Maximum Width
390 Mm
Maximum Depth
190 Mm
Net Weight
25 Kg
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
5 - 95 % Rh
Compliances
Approvals
BIS

Documentation

Item Catalogue
Leaflet-UPS-INX-1-3kVA-standard-and-extended-6a-models-en-in
pdf